  -V15.06 Upgrade logs 
  
  1.Fixed a bug where parameters were lost after BMS restart. The bug is caused by a logical error in the parameter entered by the user.
  2.Change the default configuration parameters to LPF to improve security.
  2.Optimized JKBMS Modbus protocol, added RCV RFV register support. The protocol must use the PC software version V2.5.0。
  3.Fixed the Bug that the hardware version may be incorrect in the device information.
  4.Add battery low temperature alarm to dry triggers.
                                                              -@2024-01-09 by JKBMS
															  
  -V15.09 Upgrade logs 													  
  1.Fix a bug, parameters (RFV Time) Storage failure.
  2.Change the default configuration parameters to LTO to improve security.
  
                                                              -@2024-01-12 by JKBMS

  -V15.10 Upgrade logs 
  1. Button shutdown logic detection and optimization.
  2. Bluetooth communication optimization.
  
                                                              -@2024-01-17 by JKBMS
															  
  -V15.11 Upgrade logs 
  1. DRY Trigger source added "12 - Remote Control "option
  2. The LCD V2.0 protocol is added to the protocol library, which supports charging and discharging through the touch screen.
  3. The Victor protocol allows the vendor name to be changed by writing the user's private data.
  4. Fix a bug, parameters (RFV Time) Storage failure.
                                                              -@2024-03-01 by JKBMS
                                                              
  V15.17  Upgrade logs
  1. Upgrade the LCD protocol to support 1.1 and connection instructions.
  2. Optimize the SWUART code.
  3. Fix the Bug of the calf communication protocol.
  4. Added support for JK-BD6A20S20P JK-BD6A24S20P.
  5. Add intermittent alarm function.
  6. Add the emergency trigger button and the emergency time parameter.
  1. Added LUXPOWERTEK inverter support.
  
                                                              @2024-03-31 by JKBMS                  
                                                              
  V15.23  Upgrade logs
  1. Optimize the alarm reporting logic of parallel current limiting module.
  2. Optimize the JKBMS-CAN communication protocol.
  3. JKBMS RS485_Modbus Add Buad9600bps.
  4. Added support for JK-BD6A20S20P JK-BD6A24S20P.
  5. fix a bug about DEYE inverter.
  
                                                              @2024-05-27 by JKBMS

  V15.24  Upgrade logs
  1. Fixed a Bug about LCD display in V15.23.
  
                                                              @2024-06-04 by JKBMS

  V15.26  Upgrade logs
  1. Fixed a Bug about DEYE inverter CAN communication protocol.
  2. Fixed a Bug about Growatt inverter RS485 communication protocol.
  
                                                              @2024-06-20 by JKBMS


  V15.27  Upgrade logs
  1. Added support for the PYLON RS485 communication protocol.
  2. Added support for the MEGAREVO CAN communication protocol.
  3. Added product model JK-B2A24S30P.
                                                              @2024-06-28 by JKBMS
                                                              
  V15.30  Upgrade logs
  1.The default value of the UTP is changed 
    (the UTP is changed from -20 to 2 and the UTPR is changed from -10 to 7).
  2.Adjust the alarm mechanism in parallel mode.
    (Only when all battery packs produce the same alarm is reported to the bus, 
     otherwise the alarm of a single battery pack is reported to the bus in the form of a warning.)
  3.Fixed a negative current issue with the Victorn communication protocol 
    (resolved that the power consumption could not be displayed in the VRM).
  4.The maximum and minimum cells are reported in parallel mode, 
    and the maximum and minimum temperatures are changed to the extreme values of the entire battery group.
  5.Added battery type option in Real-Status.
  6.Added the ability to disable or enable Bluetooth by double-clicking the button to improve user data security.
  7.Added the ability to count discharge energy and charge energy.
  
                                                              @2024-08-25 by JKBMS                                                  
                                                              